• Multiwfn forum

    Multiwfn official website: http://www.shanxitv.org/multiwfn. Multiwfn forum in Chinese: http://bbs.keinsci.com/wfn. E-mail of admin: sobereva[at]sina.com

    You are not logged in.

    #1 2019-11-16 05:42:52

    sobereva
    Tian Lu (Multiwfn developer)
    From: Beijing
    Registered: 2017-09-11
    Posts: 1,468
    Website

    Calculating RESP charge for excited state by using Gaussian+Multiwfn

    A Multiwfn user asked me how to calculate RESP charge for excited state by using Gaussian+Multiwfn, here I describe the easiest way:

    Using below input file (H2CO.gjf) to carry out a excited state calculation by Gaussian via TDDFT (note that the "root" option is default to 1).

    # B3LYP/def2SVP TD density pop=MK IOp(6/33=2,6/42=6)
    
    test
    
    0 1
     C                  0.00000000    0.00000000    0.52887991
     H                  0.00000000    0.93775230    1.12379107
     O                  0.00000000    0.00000000   -0.67757652
     H                  0.00000000   -0.93775230    1.12379107

    Boot up Multiwfn and input below commands:

    H2CO.gjf
    7  // Population analysis
    18   // RESP module
    8  // Will load ESP fitting points and ESP values from Gaussian output file
    1  // Standard two-steps RESP fitting
    H2CO.out   // The Gaussian output file
    Now the RESP charge for S1 state of H2CO is obtained, as shown below.

       Center      Charge
         1(C )   -0.322094
         2(H )    0.196640
         3(O )   -0.071185
         4(H )    0.196640
     Sum of charges:    0.000000
     RMSE:    0.004375   RRMSE:    0.344520

    If RESP charge for e.g. S3 is needed, use "TD(nstates=5,root=2)" instead of TD in Gaussian input file.