Thank you for your guidance, I have a working script for this now.
Best,
dmpz
Multiwfn also supports calculating polarizability contribution by atoms via integrating polarizability density in every atom space, but the result is dependent of the choice origin.
]]>Sir, After doing IRI analysis I obtain output .txt then copying IRIscatter.gnu to Gnuplot. then running gnuplot IRIscatter.gnu in GNUPLOT folder. I found gnuplot iriscatter.gnu
^
invalid command
What to do to view IRIscatter .ps.
Yours sincerely,
Partha
It is best to upload your screenshot. I can hardly understand your situation.
]]>I don't know which shell did you use, if powershell was used, note that the default encoding is UTF-16. I highly recommend to use cmd instead.
]]>Please note that .wfn file of CP2K is completely different from the common .wfn file in the wavefunction analysis field. The .wfn file produced by CP2K calculation has a private format, and it is in binary form; in contrast, the .wfn file that can be loaded to / exported by Multiwfn is a plain text file. Multiwfn is unable to produce the private .wfn file of CP2K.
Best,
Tian
]]>Sir, As per your instruction in Multiwfn mannual(4.2.5) you specify the VMD.bat file for easy plot high quality AIM topology in VMD visualization. But the VMD.bat is not found in script. Will you help.
Yours sincerely,
Partha
"examples\scripts\AIM.bat" can be found in Multiwfn binary package
]]>The negative value comes from the known theoretical deficiency of Mulliken population. If you are only interested in atomic contribution, I suggest using Hirshfeld method to evaluate the composition instead, Hirshfeld method is much more robust and the result is always nonnegative.
Best,
Tian
]]>Can you please guide me to what is wrong with my calculation.
]]>It is noteworthy that Multiwfn is able to calculate <r^2> for all electrons, which is more closely related to spatial distribution of total electron density. See example in Section 4.300.5 of Multiwfn manual on how to calculate it, and see my blog article for discussion http://www.shanxitv.org/616 (in Chinese).
]]>If the Gaussian input files were generated previously (i.e. not generated this time), and you have run them by Gaussian to obtain output files, there are two possible reasons of the crash:
(1) The Gaussian tasks were not finished successfully. Please manually check end of the output file to check this point.
(2) The input file you loaded into Multiwfn this time is different to that loaded previously, or the grid setting this time is different to the previous one, and thus Multiwfn is unable to load the expected number of Bq from the Gaussian output file.
If you really cannot find solution, please send your input file that loaded into Multiwfn, Gaussian output file (compressing it first), and all commands you inputted in Multiwfn to my E-mail, I will check (I am fully occupied recently, I can only reply E-mail at the end of this month).
Best,
Tian
]]>